Man page - wj200_vfd(1)

Packages contains this manual

Manual

WJ200_VFD

NAME
SYNOPSIS
PINS
PARAMETERS
LICENSE

NAME

wj200_vfd - Hitachi wj200 modbus driver

SYNOPSIS

wj200_vfd

PINS

wj200-vfd. N .commanded-frequency float in

Frequency of vfd

wj200-vfd. N .reverse bit in

1 when reverse 0 when forward

wj200-vfd. N .run bit in

run the vfd

wj200-vfd. N .enable bit in

1 to enable the vfd. 0 will remote trip the vfd, thereby disabling it.

wj200-vfd. N .is-running bit out

1 when running

wj200-vfd. N .is-at-speed bit out

1 when running at assigned frequency

wj200-vfd. N .is-ready bit out

1 when vfd is ready to run

wj200-vfd. N .is-alarm bit out

1 when vfd alarm is set

wj200-vfd. N .motor-current float out

Output current in amps

wj200-vfd. N .heatsink-temp float out

Temperature of drive heatsink

wj200-vfd. N .watchdog-out bit out

Alternates between 1 and 0 after every update cycle. Feed into a watchdog component to ensure vfd driver is communicating with the vfd properly.

PARAMETERS

wj200-vfd. N .mbslaveaddr u32 rw

Modbus slave address

LICENSE

GPLv2 or greater