Man page - dispread(1)
Packages contains this manual
- profcheck(1)
- cb2ti3(1)
- splitti3(1)
- mppprof(1)
- mppcheck(1)
- synthcal(1)
- fakeread(1)
- ccxxmake(1)
- iccdump(1)
- printcal(1)
- chartread(1)
- oeminst(1)
- applycal(1)
- dispwin(1)
- xicclu(1)
- colverify(1)
- spec2cie(1)
- dispcal(1)
- revfix(1)
- printtarg(1)
- txt2ti3(1)
- average(1)
- colprof(1)
- illumread(1)
- targen(1)
- ls2ti3(1)
- mpplu(1)
- timage(1)
- collink(1)
- cxf2ti3(1)
- greytiff(1)
- icclu(1)
- synthread(1)
- invprofcheck(1)
- cctiff(1)
- kodak2ti3(1)
- specplot(1)
- extractttag(1)
- viewgam(1)
- iccgamut(1)
- spotread(1)
- refine(1)
- scanin(1)
- tiffgamut(1)
- extracticc(1)
- dispread(1)
apt-get install argyll
Manual
READ
NAMEDESCRIPTION
SYNOPSIS
NAME
Read - Read a Display.
DESCRIPTION
Read a Display
SYNOPSIS
dispread [options] outfile
|
-v |
Verbose mode |
-display displayname Choose X11 display name
-d n[,m]
Choose the display n from the following list (default 1) Optionally choose different display m for VideoLUT access
1 = ’Screen 1, Output DVI-I-1 at 0, 0, width 1920, height 1080’
-dweb[ :port]
Display via a web server at port (default 8080)
-c listno
Set communication port from the following list (default 1)
** No ports found **
|
-p |
Use telephoto mode (ie. for a projector) (if available) |
-k file.cal
Load calibration file into display while reading
-K file.cal
Apply calibration file to test values while reading
|
-s |
Save spectral information (default don’t save) |
-P ho,vo,ss[,vs]
Position test window and scale it ho,vi: 0.0 = left/top, 0.5 = center, 1.0 = right/bottom etc. ss: 0.5 = half, 1.0 = normal, 2.0 = double etc.
|
-F |
Fill whole screen with black background |
|||
|
-n |
Don’t set override redirect on test window |
|||
|
-E |
Encode the test values for video range 16..235/255 |
|||
|
-J |
Run instrument calibration first (used rarely) |
|||
|
-N |
Disable initial calibration of instrument if possible |
|||
|
-H |
Use high resolution spectrum mode (if available) |
|||
|
-w |
Disable normalisation of white to Y = 100 |
-X file.ccmx
Apply Colorimeter Correction Matrix
-X file.ccss
Use Colorimeter Calibration Spectral Samples for calibration
-Q observ
Choose CIE Observer for spectrometer or CCSS colorimeter data: 1931_2 (def), 1964_10, S&B 1955_2, shaw, J&V 1978_2, 1964_10c
|
-I b|w |
Drift compensation, Black: -Ib , White: -Iw , Both: -Ibw |
-Y R:rate
Override measured refresh rate with rate Hz
|
-Y A |
Use non-adaptive integration time mode (if available). |
|||
|
-Y p |
Don’t wait for the instrument to be placed on the display |
-C "command"
Invoke shell "command" each time a color is set
-M "command"
Invoke shell "command" each time a color is measured
-W n|h|x
Override serial port flow control: n = none, h = HW, x = Xon/Xoff
-D [level]
Print debug diagnostics to stderr
outfile
Base name for input[ti1]/output[ti3] file