Man page - hpialarms(1)

Packages contains this manual

Manual

hpialarms

NAME
SYNOPSIS
DESCRIPTION
OPTIONS
Help Options:
Application Options:
SAMPLE OUTPUT
SEE ALSO
AUTHORS

NAME

hpialarms - A openhpi sample application that shows "Alarm Control" management instruments

SYNOPSIS

hpialarms [-D id] [-N host[:port]] [-C <cfgfile>]
[-a 1|0][-b 1|0][-c 1|0][-m 1|0][-n 1|0][-p 1|0][-i n][-o][-X][-h]
hpialarms [--domain=id] [--host=host[:port]] [--cfgfile=file]
[--diska=1|0] [--diskb=1|0] [--critical=1|0] [--major=1|0]
[--minor=1|0] [--power=1|0] [--chassisid=n] [--all] [--debug] [--help]

DESCRIPTION

hpialarms walks the RPT (Resource Presence Table) for resources that have "Alarm Control" management instruments (SAHPI_CTRL_LED).

If no domain or host is selected, hpialarms uses the default domain as specified in the openhpiclient.conf file.

OPTIONS

(No Option) Display alarm states

Help Options:

-h , --help

Show help options

Application Options:

-c 1|0 , - -critical = 1|0

Set critical alarm on|off

-m 1|0 , - -major = 1|0

Set major alarm on|off

-n 1|0 , - -minor = 1|0

Set minor alarm on|off

-a 1|0 , - -diska = 1|0

Set diska alarm on|off

-b 1|0 , - -diskb = 1|0

Set diskb alarm on|off

-p 1|0 , - -power = 1|0

Set power alarm on|off

-i n , - -chassisid = n

Set chassis id on for n seconds

-o , - -all

Set all alarms off

-D nn , --domain = nn

Select domain id nn

-X , --debug

Display debug messages

-N "host[:port]" , --host = "host[:port]"

Open session to the domain served by the daemon at the specified URL (host:port). This option overrides the OPENHPI_DAEMON_HOST and OPENHPI_DAEMON_PORT environment variables. If host contains ’:’ (for example IPv6 address) then enclose it in square brackets. For example: "[::1]" or "[::1]:4743" .

-C "file" , --cfgfile = "file"

Use passed file as client configuration file. This option overrides the OPENHPICLIENT_CONF environment variable.

SAMPLE OUTPUT

hpialarmpanel ver 0.6
RptInfo: UpdateCount = 5, UpdateTime = 8a2dc6c0
rptentry[0] resourceid=1 tag: Mullins
RDR[45]: ctltype=2:1 oem=0 Chassis Identify Control
RDR[48]: ctltype=0:1 oem=10 Front Panel Power Alarm LED state = off
RDR[51]: ctltype=0:1 oem=13 Front Panel Minor Alarm LED state = ON
RDR[46]: ctltype=0:0 oem=0 Cold Reset Control
RDR[49]: ctltype=0:1 oem=11 Front Panel Critical Alarm LED state = off
RDR[50]: ctltype=0:1 oem=12 Front Panel Major Alarm LED state = off

SEE ALSO

hpi_shell
hpidomain hpigensimdata hpireset hpitop
hpiel hpiinv hpisensor hpitree
hpievents hpionIBMblade hpisettime hpiwdt
hpifan hpipower hpithres hpixml
ohdomainlist ohhandler ohparam

AUTHORS

Authors of this man page:

Peter D Phan (pdphan@users.sourceforge.net)
Ulrich Kleber (ulikleber@users.sourceforge.net)
Anton Pak (avpak@users.sourceforge.net)