Man page - ds2761(3)
Packages contains this manual
Manual
DS2760
NAMESYNOPSIS
Temperature Voltage and Current.
Thermocouple
Weather Station
FAMILY CODE
SPECIAL PROPERTIES
amphours
current
currentbias
lock.[0-1|ALL]
memory
pages/pages.[0-1|ALL]
PIO
sensed
temperature
vbias
vis
volt
volthours
THERMOCOUPLE
typeX/
typeX/range_low typeX/ranges_high
typeX/temperature
WEATHER STATION
WS603
WS603/temperature
WS603/wind_speed
WS603/direction
WS603/volt
WS603/calibration/wind_speed
WS603/calibration/direction
WS603/light/intensity
WS603/light/threshold
WS603/LED/status
WS603/LED/model
WS603/LED/model
OBSCURE PROPERTIES
cc ce coc dc de doc mstr ov pmod swen uv
defaultpmod defaultswen
STANDARD PROPERTIES
address
r_address
crc8
family
id
r_id
locator
r_locator
present (DEPRECATED)
type
ALARMS
DESCRIPTION
1-Wire
OWFS design
DS2760 DS2761 DS2762
ADDRESSING
DATASHEET
SEE ALSO
Programs
Configuration and testing
Language bindings
Clocks
ID
Memory
Switches
Temperature
Humidity
Voltage
Resistance
Multifunction (current, voltage, temperature)
Counter
LCD Screen
Crypto
Pressure
Moisture
AVAILABILITY
AUTHOR
NAME
DS2760, DS2761, DS2762 - High-Precision Li+ Battery Monitor
SYNOPSIS
Temperature Voltage and Current.
30
[.]XXXXXXXXXXXX[XX][/[
amphours
|
current
|
currentbias
|
lock.[0-1|ALL]
|
memory
|
pages/page.[0-1|ALL]
|
PIO
|
sensed
|
temperature
|
vbias
|
vis
|
volt
|
volthours
|
cc
|
ce
|
coc
|
defaultpmod
|
defaultswen
|
dc
|
de
|
doc
|
mstr
|
ov
|
ps
|
pmod
|
swen
|
uv
|
address
|
crc8
|
id
|
locator
|
r_address
|
r_id
|
r_locator
|
type
]]
Thermocouple
30 [.]XXXXXXXXXXXX[XX][/[ temperature | typeX/range_low | typeX/range_high | typeX/temperature ]]
Weather Station
30
[.]XXXXXXXXXXXX[XX][/[
WS603/temperature
|
WS603/wind_speed
|
WS603/direction
|
WS603/volt
|
WS603/LED/status
|
WS603/LED/control.ALL
|
WS603/LED/model
|
WS603/calibrationwind_speed
|
WS603/calibration/direction
|
WS603/light/intensity
|
WS603/light/threshold
FAMILY CODE
30
SPECIAL PROPERTIES
amphours
read-write,
floating point
Accumulated amperage read by current sensor. Units are in
Amp-hr
(Assumes internal 25mOhm resistor). Derived
from
volthours
/ Rinternal.
Formally
amphours
is the integral of
current -
currentbias
over time.
current
read-only,
floating point
Current reading. Units are in
Amp
(Assumes internal
25 mOhm resistor). Derived from
vis
/ Rinternal.
currentbias
read-write,
floating point
Fixed offset applied to each
current
measurement.
Used in the
amphours
value. Assumes internal 25mOhm
resistor. Units are
Amp
and range from -.08A to .08A.
Derived from
vbias
/ Rinternal.
lock.[0-1|ALL]
read-write,
yes-no
Lock either of the two eprom pages to prevent further
writes. Apparently setting
lock
is permanent.
memory
read-write,
binary
Access to the full 256 byte memory range. Much of this space
is reserved or special use. User space is the
page
area.
See the
DATASHEET
for a full memory map.
pages/pages.[0-1|ALL]
read-write,
binary
Two 16 byte areas of memory for user application.
The
lock
property can prevent further alteration.
NOTE that the
page
property is different from the
common
OWFS
implementation in that all of
memory
is not accessible.
PIO
write-only,
yes-no
Controls the PIO pin allowing external switching.
Writing "1" turns the PIO pin on (conducting).
Writing "0" makes the pin non-conducting. The
logical state of the voltage can be read with the
sensed
property. This will reflect the current
voltage at the pin, not the value sent to
PIO
Note also that
PIO
will also be altered by the
power-status of the
DS2670
See the datasheet for
details.
sensed
read-only,
yes-no
The logical voltage at the PIO pin. Useful only if the
PIO
property is set to "0"
(non-conducting).
Value will be 0 or 1 depending on the voltage threshold.
temperature
read-only,
floating point
Temperature
read by the chip at high resolution
(˜13 bits). Units are selected from the invoking
command line. See
owfs(1)
or
owhttpd(1)
for
choices. Default is Celsius.
Conversion is continuous.
vbias
read-write,
floating point
Fixed offset applied to each
vis
measurement. Used
for the
volthours
value. Units are in
Volts.
Range -2.0mV to 2.0mV
vis
read-only,
floating point
Current sensor reading (unknown external resistor). Measures
the voltage gradient between the Vis pins. Units are in
Volts
The
vis
readings are integrated over time to provide
the
volthours
property.
The
current
reading is derived from
vis
assuming the internal 25 mOhm resistor is employed. There is
no way to know this through software.
volt
read-only,
floating point
Voltage read at the voltage sensor;. This is separate from
the
vis
voltage that is used for
current
measurement. Units are
Volts
Range is between 0 and 4.75V
volthours
read-write,
floating point
Integral of
vis - vbias
over time. Units are in
volthours
THERMOCOUPLE
typeX/
directory
Thermocouple circuit using the
DS2760
to read the
Seebeck voltage and the reference temperature. Since the
type interpretation of the values read depends on the type
of thermocouple, the correct directory must be chosen.
Supported thermocouple types include types B, E, J, K, N, R,
S and T.
typeX/range_low typeX/ranges_high
read-only,
flaoting point
The lower and upper temperature supported by this
thermocouple (at least by the conversion routines). In the
globally chosen temperature units.
typeX/temperature
read-only,
floating point
Thermocouple temperature. Requires a voltage and temperature
conversion. Returned in globally chosen temperature units.
Note: there are two types of temperature measurements
possible. The
temperature
value in the main device
directory is the reference temperature read at the chip. The
typeX/temperature
value is at the thermocouple
junction, probably remote from the chip.
WEATHER STATION
WS603
directory
Weather station from
AAG electronica
that includes
temperature, wind speed, wind direction, light sensor and
LED lights.
WS603/temperature
read-only,
floating-point
Uses the
DS2760
temperature sensor. This is
equivalent to the
temperature
value. Again in the
specificed temperature scale, default Celsius.
WS603/wind_speed
read_only,
floating-point
Readings from the anometer, scaled using the
WS603/calibration/wind_speed
WS603/direction
read_only,
unsigned integer
Wind direction, using the following table
|
1 |
N |
|||
|
2 |
NNE |
|||
|
3 |
NE |
|||
|
4 |
NEE |
|||
|
5 |
E |
|||
|
6 |
EES |
|||
|
7 |
ES |
|||
|
8 |
ESS |
|||
|
9 |
S |
|||
|
10 |
SSW |
|||
|
11 |
SW |
|||
|
12 |
SWW |
|||
|
13 |
W |
|||
|
14 |
WWN |
|||
|
15 |
WN |
|||
|
16 |
WWN |
Values are adjusted (internally) by the WS603/calibration/direction property
WS603/volt
read-only,
unsigned integer
Voltage value from the
WS603
device. Units and
significance is unclear.
WS603/calibration/wind_speed
read-write,
unsigned integer
Value between 1 and 200 for wind speed scaling. Values on of
this range are ignored and the default value of 100
used.
WS603/calibration/direction
read-write,
unsigned integer
Adjustment of wind direction. See datasheet.
WS603/light/intensity
read-only,
unsigned integer
Uncalibrated value from an internal light sensor. Used for
control of LED display (daytime vs nighttime).
WS603/light/threshold
read-only,
unsigned integer
Threshold for internal light sensor. Used for control of LED
display (daytime vs nighttime).
Value is set as value 4 of the array passed to WS603/LED/control
WS603/LED/status
read-only,
unsigned integer
Status of LED lights intensities. See datasheet.
Value is set as values 2 and 3 of the array passed to WS603/LED/control
WS603/LED/model
read-only,
unsigned integer
What factors control LED display. See datasheet.
Value is set as value 1 of the array passed to WS603/LED/control.ALL
WS603/LED/model
write-only,
unsigned integer array of 4 values
Four integers sent to control LED display. All four values
must be sent, comma separated.
|
0 |
Light mode |
|||
|
1 |
Light status |
|||
|
2 |
Light level |
|||
|
3 |
Light threshold |
OBSCURE PROPERTIES
cc ce coc dc de doc mstr ov pmod swen uv
varies,
yes-no
Bit flags corresponding to various battery management
functions of the chip. See the
DATASHEET
for details
of the identically named entries.
In general, writing "0" corresponds to a 0 bit
value, and non-zero corresponds to a 1 bit value.
defaultpmod defaultswen
read-write,
yes-no
Default power-on state for the corresponding properties.
STANDARD PROPERTIES
address
r_address
read-only,
ascii
The entire 64-bit unique ID. Given as upper case hexadecimal
digits (0-9A-F).
address
starts with the
family
code
r address
is the
address
in reverse order, which
is often used in other applications and labeling.
crc8
read-only,
ascii
The 8-bit error correction portion. Uses cyclic redundancy
check. Computed from the preceding 56 bits of the unique ID
number. Given as upper case hexadecimal digits (0-9A-F).
family
read-only,
ascii
The 8-bit family code. Unique to each
type
of device.
Given as upper case hexadecimal digits (0-9A-F).
id
r_id
read-only,
ascii
The 48-bit middle portion of the unique ID number. Does not
include the family code or CRC. Given as upper case
hexadecimal digits (0-9A-F).
r id
is the
id
in reverse order, which is often
used in other applications and labeling.
locator
r_locator
read-only,
ascii
Uses an extension of the 1-wire design from iButtonLink
company that associated 1-wire physical connections with a
unique 1-wire code. If the connection is behind a
Link
Locator
the
locator will show a unique 8-byte number
(16 character hexadecimal) starting with family code FE.
If no
Link Locator
is between the device and the
master, the
locator
field will be all FF.
r locator
is the
locator
in reverse order.
present (DEPRECATED)
read-only,
yes-no
Is the device currently
present
on the 1-wire
bus?
type
read-only,
ascii
Part name assigned by Dallas Semi. E.g.
DS2401
Alternative packaging (iButton vs chip) will not be
distiguished.
ALARMS
None.
DESCRIPTION
1-Wire
1-wire is a wiring protocol and series of devices designed and manufactured by Dallas Semiconductor, Inc. The bus is a low-power low-speed low-connector scheme where the data line can also provide power.
Each device is uniquely and unalterably numbered during manufacture. There are a wide variety of devices, including memory, sensors (humidity, temperature, voltage, contact, current), switches, timers and data loggers. More complex devices (like thermocouple sensors) can be built with these basic devices. There are also 1-wire devices that have encryption included.
The 1-wire scheme uses a single bus master and multiple slaves on the same wire. The bus master initiates all communication. The slaves can be individually discovered and addressed using their unique ID.
Bus masters come in a variety of configurations including serial, parallel, i2c, network or USB adapters.
OWFS design
OWFS is a suite of programs that designed to make the 1-wire bus and its devices easily accessible. The underlying principle is to create a virtual filesystem, with the unique ID being the directory, and the individual properties of the device are represented as simple files that can be read and written.
Details of the individual slave or master design are hidden behind a consistent interface. The goal is to provide an easy set of tools for a software designer to create monitoring or control applications. There are some performance enhancements in the implementation, including data caching, parallel access to bus masters, and aggregation of device communication. Still the fundamental goal has been ease of use, flexibility and correctness rather than speed.
DS2760 DS2761 DS2762
The DS2760 (3) is a class of battery charging controllers. There are minor hardware difference between the DS2760, DS2761 and DS2762 battery chip, but they are indistinguishable to the software.
A number of interesting devices can be built with the DS276x including thermocouples. Support for thermocouples in built into the software, using the embedded thermister as the cold junction temperature.
For an explanation of the differences between the DS276x variants, see Dallas Application Note 221.
ADDRESSING
All 1-wire
devices are factory assigned a unique 64-bit address. This
address is of the form:
Family Code
8 bits
Address
48 bits
|
CRC |
8 bits |
Addressing under OWFS is in hexadecimal, of form:
01.123456789ABC
where 01 is an example 8-bit family code, and 12345678ABC is an example 48 bit address.
The dot is optional, and the CRC code can included. If included, it must be correct.
DATASHEET
http://pdfserv.maxim-ic.com/en/ds/DS2760.pdf
http://pdfserv.maxim-ic.com/en/an/app221.pdf
http://www.aag.com.mx/aagusa/contents/en-us/Description%20of%20WSV3%20Interface%20(1-wire).pdf
SEE ALSO
Programs
owfs (1) owhttpd (1) owftpd (1) owserver (1) owdir (1) owread (1) owwrite (1) owpresent (1) owtap (1)
Configuration and testing
owfs (5) owtap (1) owmon (1)
Language bindings
owtcl (3) owperl (3) owcapi (3)
Clocks
DS1427 (3) DS1904 (3) DS1994 (3) DS2404 (3) DS2404S (3) DS2415 (3) DS2417 (3)
ID
DS2401 (3) DS2411 (3) DS1990A (3)
Memory
DS1982 (3) DS1985 (3) DS1986 (3) DS1991 (3) DS1992 (3) DS1993 (3) DS1995 (3) DS1996 (3) DS2430A (3) DS2431 (3) DS2433 (3) DS2502 (3) DS2506 (3) DS28E04 (3) DS28EC20 (3)
Switches
DS2405 (3) DS2406 (3) DS2408 (3) DS2409 (3) DS2413 (3) DS28EA00 (3) InfernoEmbedded (3)
Temperature
DS1822 (3) DS1825 (3) DS1820 (3) DS18B20 (3) DS18S20 (3) DS1920 (3) DS1921 (3) DS1821 (3) DS28EA00 (3) DS28E04 (3) EDS0064 (3) EDS0065 (3) EDS0066 (3) EDS0067 (3) EDS0068 (3) EDS0071 (3) EDS0072 (3) MAX31826 (3)
Humidity
DS1922 (3) DS2438 (3) EDS0065 (3) EDS0068 (3)
Voltage
DS2450 (3)
Resistance
DS2890 (3)
Multifunction (current, voltage, temperature)
DS2436 (3) DS2437 (3) DS2438 (3) DS2751 (3) DS2755 (3) DS2756 (3) DS2760 (3) DS2770 (3) DS2780 (3) DS2781 (3) DS2788 (3) DS2784 (3)
Counter
DS2423 (3)
LCD Screen
LCD (3) DS2408 (3)
Crypto
DS1977 (3)
Pressure
DS2406 (3) TAI8570 (3) EDS0066 (3) EDS0068 (3)
Moisture
EEEF (3) DS2438 (3)
AVAILABILITY
http://www.owfs.org
AUTHOR
Paul Alfille (paul.alfille@gmail.com)