Man page - ds1921(3)
Packages contains this manual
Manual
DS1921-Thermochron
NAMESYNOPSIS
FAMILY CODE
SPECIAL PROPERTIES
about/measuring
about/resolution
about/samples
about/temphigh
about/templow
about/version
clock/date
clock/running
clock/udate
histogram/counts.0 ... histogram/counts.62 histogram/counts.ALL
histogram/elements
histogram/gap
histogram/temperature.0 ... histogram/temperature.62histogram/temperature.ALL
log/date.0 ... log/date.2047 log/date.ALL
log/elements
log/temperature.0 ... log/temperature.2047 log/temperature.ALL
log/udate.0 ... log/udate.2047 log/udate.ALL
memory
overtemp/count.0 ... overtemp/count.11 overtemp/count.ALL
undertemp/count.0 ... undertemp/count.11 undertemp/count.ALL
overtemp/end.0 ... overtemp/end.11 overtemp/end.ALL
undertemp/end.0 ... undertemp/end.11 undertemp/end.ALL
overtemp/date.0 ... overtemp/date.11 overtemp/date.ALL
undertemp/date.0 ... undertemp/date.11 undertemp/date.ALL
overtemp/elements
undertemp/elements
overtemp/temperature
undertemp/temperature
overtemp/udate.0 ... overtemp/udate.11 overtemp/udate.ALL
undertemp/udate.0 ... undertemp/udate.11 undertemp/udate.ALL
pages/page.0 ... pages/page.15 pages/page.ALL
temperature
STANDARD PROPERTIES
address
r_address
crc8
family
id
r_id
locator
r_locator
present (DEPRECATED)
type
ALARMS
DESCRIPTION
1-Wire
OWFS design
DS1921 Thermochron
ADDRESSING
DATASHEET
SEE ALSO
Programs
Configuration and testing
Language bindings
Clocks
ID
Memory
Switches
Temperature
Humidity
Voltage
Resistance
Multifunction (current, voltage, temperature)
Counter
LCD Screen
Crypto
Pressure
Moisture
AVAILABILITY
AUTHOR
NAME
DS1921 - Thermochron temperature logging iButton.
SYNOPSIS
Temperature logging iButton.
21
[.]XXXXXXXXXXXX[XX][/[
about/[measuring| resolution| samples| templow| temphigh|
version]
|
clock/[date| running| udate]
|
histotgram/[counts[0-62|ALL]| gap|
temperature[counts[0-62|ALL]]
|
log[date[0-2047|ALL]| elements| temperature[0-2047|ALL]|
udate[0-2047|ALL]]
|
memory
|
mission/[date| delay| easystart| frequency| rollover|
running| samples| sampling| udate]
|
overtemp/[date[0-11|ALL]| elements| end[0-11|ALL]|
count[0-11|ALL]| temperature[0-11|ALL]| udate[0-11|ALL]]
|
pages/page.[0-15|ALL]
|
temperature
|
undertemp/[date[0-11|ALL]| elements|end[0-11|ALL]|
count[0-11|ALL]| temperature[0-11|ALL]| udate[0-11|ALL]]
|
address
|
crc8
|
id
|
locator
|
r_address
|
r_id
|
r_locator
|
type
]]
FAMILY CODE
21
SPECIAL PROPERTIES
about/measuring
read-only,
yes-no
Is this
DS1921
currently
measuring
a
temperature?
about/resolution
read-only,
floating point
What is the
resolution
of the temperature measurments
(in the current temperature scale).
about/samples
read-only,
unsigned integer
How many total temperature measurements has this
DS1921
performed?
about/temphigh
read-only,
floating point
Highest temperature this
DS1921
can measure (in the
current temperature scale).
about/templow
read-only,
floating point
Lowest temperature this
DS1921
can measure (in the
current temperature scale).
about/version
read-only,
ascii
Specific
version
of this
DS1921.
clock/date
read-write,
ascii
26 character date representation of the internal time stored
in this
DS1921.
Increments once per second while
clock/running
Setting
date
to a null string will put the current
system time.
Accepted date formats are:
Sat[urday] March 12 12:23:59 2001
Apr[il] 4 9:34:56 2002
3/23/04 23:34:57
current locale setting (your system’s format)
clock/running
read-write,
yes-no
Whether the internal clock is running. This can be
explicitly set, and is automatically started by setting
clock/date
or
clock/udate
or by starting a
mission with
mission/easystart
or
mission/frequency
The main reason to stop the clock is to conserve the internal battery. The clock cannot be stopped during a mission, and the clock is essential for a mission.
clock/udate
read-write,
unsigned integer
A numeric representation of
clock/date
The number of seconds in UNIX time (since Jan 1, 1970).
histogram/counts.0 ... histogram/counts.62 histogram/counts.ALL
read-only,
unsigned integer
The number of samples in the current mission whose
temperature fell within the
histogram/temperature
to
histogram/temperature+histogram/gap
range.
histogram/elements
read-only,
unsigned integer
The number of bins in the histogram. Always 63.
histogram/gap
read-only,
floating point
The size of the histogram bin. Depends on the Thermochron
version (
about/version
) and is usually 4 times
about/resolution
Given in the current temperatature scale.
histogram/temperature.0 ... histogram/temperature.62histogram/temperature.ALL
read-only,
floating point
Lower limit of the temperature range for the corresponding
histogram bin. In the current temperature scale.
log/date.0 ... log/date.2047 log/date.ALL
read-only,
ascii
Date that the corresponding
log/temperature
was
taken, in ascii format. (See
clock/date
for more on
the format). The number of valid entries is actually
log/elements
since the log may not be full.
mission/samples gives the total number of samples that have been taken but there is only room in the log for 2048 entries. Once the log is full, mission/rollover determines the Thermochron’s behavior.
If mission/rollover is false(0), the log will hold the first 2048 samples and log/date.0 will always be the same as mission/date
If mission/rollover is true (1) then the log will hold the last 2048 samples and the entries will be shifted down with each new sample.
Note the OWFS code "untwists" the rollover behavior. The data will always be a linear array of earliest to latest.
ALL is the all data elements comma separated.
log/elements
read-only,
unsigned integer
Number of valid entries in the log.
OWFS
offers the
full 2048 values in the log memory, but not that many
samples may yet have been taken.
log/elements
will
range from 0 to 2048 and always be less than or equal to
mission/samples
log/temperature.0 ... log/temperature.2047 log/temperature.ALL
read-write,
floating point
The temperature readings (in the current temperature scale)
that correspond to the
log/date
sample. See
log/date
for details on the indexing scheme and
rollover behavior.
log/udate.0 ... log/udate.2047 log/udate.ALL
read-write,
unsigned integer
A numeric representation of
log/date
The number of seconds in UNIX time (since Jan 1, 1970).
memory
read-write,
binary
User available storage space. 512 bytes. Can also be
accessed as 16 pages of 32 bytes with the
pages/page.x
properties.
overtemp/count.0 ... overtemp/count.11 overtemp/count.ALL
undertemp/count.0 ... undertemp/count.11 undertemp/count.ALL
read-only,
unsigned integer
Number of sampling periods that the Thermochron stayed out
of range during a mission. Each sampling period is
mission/frequency
minutes long.
overtemp/end.0 ... overtemp/end.11 overtemp/end.ALL
undertemp/end.0 ... undertemp/end.11 undertemp/end.ALL
read-only,
ascii
End of time that the Thermochron went out of range during
the current mission. See
clock/date
for format.
Each period can be up to 255 samples in length, and span the time overtemp/date to overtemp/end ( or undertemp/date to undertemp/end ).
overtemp/date.0 ... overtemp/date.11 overtemp/date.ALL
undertemp/date.0 ... undertemp/date.11 undertemp/date.ALL
read-only,
ascii
Time that the Thermochron went out of range during the
current mission. See
clock/date
for format.
overtemp/elements
undertemp/elements
read-only,
unsigned integer
Number of entries (0 to 12) in the
overtemp
or
undertemp
array.
overtemp/temperature
undertemp/temperature
read-write,
floating point
Temperature limit to trigger alarm and error log.
overtemp/temperature
gives upper limit and
undertemp/temperature
gives lower limit.
In current temperature scale.
overtemp/udate.0 ... overtemp/udate.11 overtemp/udate.ALL
undertemp/udate.0 ... undertemp/udate.11 undertemp/udate.ALL
read-only,
unsigned integer
A numeric representation of
overtemp/date
or
undertemp/date
The number of seconds in UNIX time (since Jan 1, 1970).
pages/page.0 ... pages/page.15 pages/page.ALL
read-write,
binary
Memory is split into 16 pages of 32 bytes each. User
available. The log memory, register banks and histogram data
area are all separate from this memory area.
ALL
is an aggregate of the pages. Each page is accessed
sequentially.
temperature
read-only,
floating point
Last temperature explicitly requested. Only available when
the mission is not in progress. Value returned in in the
current temperature scale.
STANDARD PROPERTIES
address
r_address
read-only,
ascii
The entire 64-bit unique ID. Given as upper case hexadecimal
digits (0-9A-F).
address
starts with the
family
code
r address
is the
address
in reverse order, which
is often used in other applications and labeling.
crc8
read-only,
ascii
The 8-bit error correction portion. Uses cyclic redundancy
check. Computed from the preceding 56 bits of the unique ID
number. Given as upper case hexadecimal digits (0-9A-F).
family
read-only,
ascii
The 8-bit family code. Unique to each
type
of device.
Given as upper case hexadecimal digits (0-9A-F).
id
r_id
read-only,
ascii
The 48-bit middle portion of the unique ID number. Does not
include the family code or CRC. Given as upper case
hexadecimal digits (0-9A-F).
r id
is the
id
in reverse order, which is often
used in other applications and labeling.
locator
r_locator
read-only,
ascii
Uses an extension of the 1-wire design from iButtonLink
company that associated 1-wire physical connections with a
unique 1-wire code. If the connection is behind a
Link
Locator
the
locator will show a unique 8-byte number
(16 character hexadecimal) starting with family code FE.
If no
Link Locator
is between the device and the
master, the
locator
field will be all FF.
r locator
is the
locator
in reverse order.
present (DEPRECATED)
read-only,
yes-no
Is the device currently
present
on the 1-wire
bus?
type
read-only,
ascii
Part name assigned by Dallas Semi. E.g.
DS2401
Alternative packaging (iButton vs chip) will not be
distiguished.
ALARMS
None.
DESCRIPTION
1-Wire
1-wire is a wiring protocol and series of devices designed and manufactured by Dallas Semiconductor, Inc. The bus is a low-power low-speed low-connector scheme where the data line can also provide power.
Each device is uniquely and unalterably numbered during manufacture. There are a wide variety of devices, including memory, sensors (humidity, temperature, voltage, contact, current), switches, timers and data loggers. More complex devices (like thermocouple sensors) can be built with these basic devices. There are also 1-wire devices that have encryption included.
The 1-wire scheme uses a single bus master and multiple slaves on the same wire. The bus master initiates all communication. The slaves can be individually discovered and addressed using their unique ID.
Bus masters come in a variety of configurations including serial, parallel, i2c, network or USB adapters.
OWFS design
OWFS is a suite of programs that designed to make the 1-wire bus and its devices easily accessible. The underlying principle is to create a virtual filesystem, with the unique ID being the directory, and the individual properties of the device are represented as simple files that can be read and written.
Details of the individual slave or master design are hidden behind a consistent interface. The goal is to provide an easy set of tools for a software designer to create monitoring or control applications. There are some performance enhancements in the implementation, including data caching, parallel access to bus masters, and aggregation of device communication. Still the fundamental goal has been ease of use, flexibility and correctness rather than speed.
DS1921 Thermochron
The DS1921 (3) is an iButton device with many intriguing functions. Essentially it monitors temperature, giving both a log of readings, and a histogram of temperature ranges. The specification is somewhat complex, but OWFS hides many of the implementation details.
While on a mission the DS1921 (3) records temperature readings in a 2048-sample log and adds them to a 62-bin histogram.
ADDRESSING
All 1-wire
devices are factory assigned a unique 64-bit address. This
address is of the form:
Family Code
8 bits
Address
48 bits
|
CRC |
8 bits |
Addressing under OWFS is in hexadecimal, of form:
01.123456789ABC
where 01 is an example 8-bit family code, and 12345678ABC is an example 48 bit address.
The dot is optional, and the CRC code can included. If included, it must be correct.
DATASHEET
http://pdfserv.maxim-ic.com/en/ds/DS2438.pdf
http://pdfserv.maxim-ic.com/en/an/humsensor.pdf
SEE ALSO
Programs
owfs (1) owhttpd (1) owftpd (1) owserver (1) owdir (1) owread (1) owwrite (1) owpresent (1) owtap (1)
Configuration and testing
owfs (5) owtap (1) owmon (1)
Language bindings
owtcl (3) owperl (3) owcapi (3)
Clocks
DS1427 (3) DS1904 (3) DS1994 (3) DS2404 (3) DS2404S (3) DS2415 (3) DS2417 (3)
ID
DS2401 (3) DS2411 (3) DS1990A (3)
Memory
DS1982 (3) DS1985 (3) DS1986 (3) DS1991 (3) DS1992 (3) DS1993 (3) DS1995 (3) DS1996 (3) DS2430A (3) DS2431 (3) DS2433 (3) DS2502 (3) DS2506 (3) DS28E04 (3) DS28EC20 (3)
Switches
DS2405 (3) DS2406 (3) DS2408 (3) DS2409 (3) DS2413 (3) DS28EA00 (3) InfernoEmbedded (3)
Temperature
DS1822 (3) DS1825 (3) DS1820 (3) DS18B20 (3) DS18S20 (3) DS1920 (3) DS1921 (3) DS1821 (3) DS28EA00 (3) DS28E04 (3) EDS0064 (3) EDS0065 (3) EDS0066 (3) EDS0067 (3) EDS0068 (3) EDS0071 (3) EDS0072 (3) MAX31826 (3)
Humidity
DS1922 (3) DS2438 (3) EDS0065 (3) EDS0068 (3)
Voltage
DS2450 (3)
Resistance
DS2890 (3)
Multifunction (current, voltage, temperature)
DS2436 (3) DS2437 (3) DS2438 (3) DS2751 (3) DS2755 (3) DS2756 (3) DS2760 (3) DS2770 (3) DS2780 (3) DS2781 (3) DS2788 (3) DS2784 (3)
Counter
DS2423 (3)
LCD Screen
LCD (3) DS2408 (3)
Crypto
DS1977 (3)
Pressure
DS2406 (3) TAI8570 (3) EDS0066 (3) EDS0068 (3)
Moisture
EEEF (3) DS2438 (3)
AVAILABILITY
http://www.owfs.org
AUTHOR
Paul Alfille (paul.alfille@gmail.com)